Proportioning the Compressed Air Dryer
Trying to figure out which air dryer capacity is best for you? Here are some factors to consider. Read More…
Whenever anything doesn't work properly, it's frustrating and we get it. If this is your first time experiencing troubles with your dryer, you're probably unsure where to even start. Getting your dryer repaired and back up and working is critical to keeping the moisture out to protect your piping, tools and equipment. First thing, check the cooler on the air compressor. If the inlet air temperature is too high going into the air dryer, it will over-work the dryer and it will never reach its dewpoint temperature. If the inlet air temperature is fine, then continue by checking the below items.
Below are a few items to consider if you're dryer starts acting up. For starters, always put safety first and remove the power source to the dryer before troubleshooting or attempting repairs. Also, to minimize any further damage to the air dryer.
The first thing you should be looking at if your air dryer isn't performing. If your coils are dirty, your air dryer isn't getting proper air flow. The dirty lint blocks and traps the air. Time to clean! Use a soft cloth or brush to clean dirt from the refrigeration condenser coil to allow free passage of air. The condenser may be blown clean with compressed air or, if heavily contaminated, washed with mild detergent and water.
If your have the dryer turned on and your fan does not, this is a big deal! If the fan isn't pushing air through the coils, there is no way to cool your air. Below are a few things to consider what may be causing this to happen. - Motor shortage or burnt out motor - Failed contactor - Shorted or burnt wires - Blown fuse - Bad fan pressure switch or controller
If you have moisture in your pipes that could mean 1 of 3 things. The dryer is working outside of it's rating, there is bad conditions of condensation, OR the condensate drain discharge is not working properly. Few items to try: - Check inlet air flow rate and temperature to ensure they are properly (within design parameters) working: - Check the room temperature (same as above) - Clean the condenser - Check pressure switch/fan operation - Check your coalescent filter drains
If your condensate draining isn't performing it pushes all the condensate collected back into the system. This may push the moisture back into the air compressor or into the next stage causing premature wear on your tools or equipment. Remember if your drain has failed, you'll have plenty of water downstream to help you with indicating the problem. Proper functioning and life of the drain are highly dependent on correct maintenance. Here are a few tips: - Clean the filter as often as possible (weekly) - Clean the filter in case of malfunctioning / condensate in the lines - Check the floating device position - Install drain wear kit at least once per year (part # 2200902017)
If you aren't getting any air through the dryer outlet, most likely the heat exchanger is frozen inside. Some ice is normal, but if frozen you need to take faction fast. How does something like that happen? Here's a few common reasons: 1. By-pass broken / out of calibration: If this happens, ice builds on the coils and acts as a type of insulation, further compounding the problem and allowing ice to build up even further. 2. Room temperature too low: Room temperature can not be below 32 degrees Fahrenheit and a dryer should not run lower than 35 degrees Fahrenheit. 3. Refrigerant leaks in the circuit: As the volume of circulating refrigerant declines below specifications, refrigerant temperature initially drops below freezing. Low refrigerant usually indicates a leak in the system that must be tracked down by a professional utilizing leak detection equipment, then properly sealed. Simply topping up a low refrigerant level by adding more without pinpointing and fixing the leak is not a competent repair. If ice accumulation on the coil extends beyond the dimensions of the condensate drip pan beneath the air handler, be ready with containers to catch the dripping water and prevent water damage as the ice melts.
Sizing a dryer can be tricky if you haven't done this before. Having an undersized dryer can lead to poor air quality and overworking your dryer while an over-sized dryer can waste electricity. Itβs best to make sure youβve got one sized correctly for your installation. If you arenβt sure if your dryer is sized correctly, contact us for help.
Note that the location of the compressors and dryers can make a big difference in dryer performance. The cooler the air going into the
compressor, the lower the dryer inlet temperature. If the compressor room is hot, consider moving the dryer to another, cooler location to
boost its effectiveness.
Do you have an idea for our #expertcorner?Β Let
us know!
Ash Air has been around in New Zealand since 1979, and weβve grown into a nationwide company with international support and a reputation for quality and reliability.We look after all things compressed air for your business!
Ash Air's range of Chicago Pneumatic, Alup, Pneumatech, and Quincy compressors are used extensively around the world in industries ranging from oil and gas to food, automotive and farming, and we bring you these world class compressors here in the land of the long white cloud.Our technicians are compressed air equipment experts and are dedicated to addressing customer needs. Supported by a 13 locations nationwide, Ash Air offers one of the widest selections of compressed air equipment and parts available today in New Zealand.
With Ash Air compressors, you can count on reliability and high performance for even the most demanding applications. We focus our efforts on the following:
Talk to the team today:
Proportioning the Compressed Air Dryer
Trying to figure out which air dryer capacity is best for you? Here are some factors to consider. Read More…
Maintenance budget: 8 factors to consider
Just like any other equipment, a compressed air installation also requires the necessary maintenance work during its entire lifespan. Even though maintenance costs are only about 5 to 10% of a machine's annual operating costs, failure to budget for maintenance can have potentially disastrous consequences. Read More…
The air dyer is one of the most ignored cooler in the system. A dirty condenser will cause water in the lines, or worse it will cause complete dryer failure. Read More…
Why Replace CO2 with Nitrogen in your Brewery
Using nitrogen is not about fully replacing CO2, but it can reduce their consumption of CO2 by close to 70%. Using nitrogen is about sustainability. Creating your own nitrogen is easy and will reduce the use of a greenhouse gas, which is better for the environment. It will also save you money as early as month one adding that savings to your bottom line. Read More…
What do I need to know about ICONS?
ICONS: Intelligent Connectivity System: The insight into your compressed air system, wherever you are. Learn More about ICONS in this article here! Read More…
A question that is occasionally asked by our customers to Ash Air is 'what is the cost of compressed air?'Β This article looks at the product costs involved with compressed air, as well as minimising the energy cost of compressors and cost allocation. When looking at these factors, we need to realise what causes dropped efficiency of your compressor, leading to increased costs of compressed air. Read More…